      3. KPM75 Power quality analyzer

        KPM75 is a new generation high-end power quality analyzer that follow international power quality standards and monitor all power quality parameters such as flicker, short interruptions in recorded voltage, and harmonic up to 63 measurements, etc.
        Overview Function Specifications Wiring Diagram Download

        KPM75 is a new generation high-end power quality analyzer that follow international power quality standards and monitor all power quality parameters such as flicker, short interruptions in recorded voltage, and harmonic up to 63 measurements with power data Statistics, IO signal control alarm, communication and other functions. Large graphic LCD display, pluggable function module design, widely used in key power applications, it is the ideal choice to monitor the distribution operation efficiency.


        Application occasion

        • Measure, monitor and control power distribution system parameters
        • Collect energy consumption data that cost center analysis needs
        • Power quality analysis(Harmonic, voltage interruption, flicker and so on)
        • Signal control alarm 





        Function features

        • Measure the real effective value of all-parameter
        • 63th harmonic measurement and analysis
        • Measure voltage imbalance rate, voltage deviation, frequency deviation and other power quality parameters
        • Measurement and recording voltage fluctuations and flicker, inter-harmonics and other power quality parameters
        • Short-term interruption of voltage, surge, sudden drop and other power quality events recorded
        • Demand statistics function, record the current value and maximum value
        • 0.2S four quadrant power statistics
        • Can set 4 kinds rates 8 time period multi-rate power statistics
        • RS485 communication interface, Modbus-RTU protocol, Optional Profibus-DP
        • 1 road passive optical coupler collector active pulse output
        • Can be extended 4-way passive switch value input
        • Instrument working hours, load time statistics
        • 160 * 160 graphic LCD screen, rich in content, intuitive and clear
        • Pluggable design, appearence design patents, replacement and maintenance easy




        Working power source Operating Voltage AC 85-265V/DC 80-300V
        Rated power consumption < 3VA
        Input voltage Rated voltage 57.7/100V,220/380V,380/660V
        Overvoltage capability 1.2 times rated voltage allowed, continuous work;
        2 times the rated voltage allowed 1 second
        Rated power consumption <0.5VA(per phase)
        Measurement range 5A:0-6A;  1A:0-1.2A
        Input current Rated current Default 5A, input range 1-6A;
        optional 1A, input range 1-1.2A
        Overload capacity 1.2 times rated current allowed, continuous work;
        20 times the rated current allowed 1 second
        Rated power consumption <0.4VA(per phase)
        Accuracy range 5A:>5mA;  
        1A:>0.8mA
        Measurement accuracy Voltage ±0.2%(0.01V)
        Current ±0.2%(0.01A)
        Active power ±0.2%(0.01W)
        Reactive power ±2.0%(0.01var)
        Power factor ±1.0%(0.001)
        Frequency ±0.002Hz
        Active energy ±0.2%(0.1kwh)
        Reactive energy ±2.0%(0.1kvarh)
        Measurement display Basic parameter Voltage / current, active power, reactive power, apparent power, frequency, active energy
        Power quality 2-63 harmonic distortion rate; total harmonic distortion rate; crest factor; current K factor; voltage / current imbalance rate, flicker, voltage surge, dips, short interruptions
        Demand statistics Power demand maximum, minimum and current value
        Multi-rate 8 time periods, 4 kinds of rates
        historical data Record monthly average power factor and power data for the last three months
        Communication
         
        communication port RS485,Photoelectric isolation interface
        Communication protocol Modbus-RTU, 1200-38400BPS
        Probibus-DP,9600-12Mbps
        Input,output
         
         
        Switch value input 4-way passive main line contact DI input, internal supply DC24V power supply
        Relay output 4-Way DO output, contact capacity 250VAC / 5A, 30VDC / 5A
        Pulse output 1-way passive optocoupler collector active pulse output
        Product features Display 160 * 160 large dot-matrix LCD graphics display
        Extensions function Pluggable expansion design
        Degree of protection IP54
        Dimensions 96*96*88
        Working environment Operating temperature -25℃ ~ +70℃
        Storage temperature -30℃ ~ +75℃
        Relative humidity 5% ~ 95% No condensation
        Altitude Not more than 4000m
        Safety Withstand voltage AC2kV/min~1mA input-output-source 
        Insulation >50MΩ 
        Electromagnetic Compatibility Surge(impact) immunity IEC61000-4-5,Level4
        Electrical fast burst immunity IEC61000-4-4,Level4
        Electrostatic discharge immunity IEC61000-4-3,Level4
        Power frequency magnetic immunity IEC61000-4-8,Level4




        Explanation
        1. The wiring diagram is suitable for high voltage three-phase three-wire system, low voltage three-phase four-wire system, regard to other system wiring. 2. Please refer to KPM75 instruction manual.
        3. Analog output AO- and switch input common COM share one terminal.
        4. Terminal that without function description is invalid.
        5. The function of dotted lines is optional.
        6. The final interpretation belongs to Compere.

        久精品免费免费理论_无码av一区二区_久久久久国产综合精品_久久天天躁狠狠躁夜夜婷

        <video id="6n12a"><dl id="6n12a"></dl></video>

            <strong id="6n12a"></strong>
            1. <video id="6n12a"></video>
            2. <output id="6n12a"><noscript id="6n12a"></noscript></output>